Ball Valves

Pegler Valve

Brass chrome plated ball valve with tee, full bore. XPress ends for copper/carbon steel/stainless steel tube

Brass chrome plated ball valve with tee, full bore. XPress ends for copper/carbon steel/stainless steel tube

SizePattern No.Pack 1 QtyPack 2 QtyCodeBarcodePrice (£) each ex VAT
15mmPS500T1105022050565877£31.13
22mmPS500T1105022050565884£47.26
28mmPS500T155022050565891£64.97
CodeDescriptionAB
243301DN15/15mm PS500T105400.30
243303DN20/22mm PS500T115510.50
243304DN25/28mm PS500T131550.75
Pegler Yorkshire reserve the right to change specifications
This is an image that shows the dimensions of the product
SizePattern No.CodeIndividual Weight (kg)Pack 1 Weight (kg)Pack 2 Weight (kg)
15mmPS500T2433010.270.272.79
22mmPS500T2433030.470.474.78
28mmPS500T2433040.710.713.68
SizePattern No.CodeKv m3/h
15mmPS500T24330117.00
22mmPS500T24330341.00
28mmPS500T24330470.00
Pegler Yorkshire reserve the right to change specifications

Valves and Fittings

Pegler Customcare 5 Year Guarantee - Terms and Conditions

Products are subject to a 5 year guarantee that is between Pegler and the final purchaser of the product.

The guarantee is subject to proof of purchase being supplied.

This guarantee does not affect any statutory rights the consumer may have in law.

The guarantee covers manufacturing or material defects and does not cover parts subject to normal wear and tear.

This product range has been designed for the use of homeowners, domestic and commercial applications and therefore the guarantee is subject to the product being properly selected for their intended service conditions.

The guarantee is not applicable where the product is fitted contrary to the conditions in the fitting instructions.

This is reinforced where valves are covered by the European Pressure Equipment Directive (PED97/23/EC) where Installation, Operating and Maintenance Instructions are supplied with each product and/or carton.

Provided it is installed correctly and receives adequate preventative maintenance it should give years of trouble –free service.

Abusive behaviour and accidental damage to the product are not covered by this guarantee.

The extent of this liability is limited to the cost of the replacement of the defective item and not to fitting or consequential damages.

SizePattern No.CodeWRAS PS500 Service ValvesWRc-NSF Press Fit
15mmPS500T243301approved by WRAS PS500 Service Valvesapproved by WRc-NSF Press Fit
22mmPS500T243303approved by WRAS PS500 Service Valvesapproved by WRc-NSF Press Fit
28mmPS500T243304approved by WRAS PS500 Service Valvesapproved by WRc-NSF Press Fit
DescriptionMinimum Operating
Pressure (bar)
Maximum Cold Working
Pressure (bar)
Maximum Hot
Working Pressure (bar)
PS500T Ball ValveNo minimum operating pressure.16 bar up to 100oC16 bar up to 100oC

Care
No regular aesthetic care is required for this product

Maintenance
A regular maintenance program is the most efficient method of ensuring longer term operational efficiency of the selected valve. Such a program would need to include a risk assessment and a planned procedure of how the maintenance will be carried out. The possibility of operational limits being exceeded and the potential hazards ensuring must be considered as part of this assessment. This should be implemented to include visual checks on the valve’s condition and any development of unforeseen conditions, which could lead to failure. The correct fitting tools and equipment should be used for valve maintenance work. Separate means of draining the pipe work must be provided when carrying out any maintenance to valves. Where there may be any system debris this could be collected and /or filtered by installation of the appropriate protective device.

For further help please contact your local engineer.

If your product is under warranty please contact the Service Support Team on: 0800 1560050

Regulations
THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC and CE MARKING
The Pressure Equipment Regulations 1999 (SI 1999/2001) have now been introduced into United Kingdom law.

Valves with a maximum allowable pressure greater than 0.5 bar are covered by these new Regulations. Valves are categorised according to their maximum working pressure, size and rising level of hazard. The level of hazard varies according to the fluid being carried. Fluids are classified as Group 1, dangerous fluids or Group 2, all other fluids including steam. The Categories designated are SEP (sound engineering practice). Valves up to and including 25mm (1”) are designated SEP regardless of the fluid group. Those identified as having increased hazard are Categorised as, I, II, III or IV. All valves designated as SEP do not bear the CE mark nor require a Declaration of Conformity. Categories I, II, III or IV carry the CE mark and require a Declaration of Conformity. Valves classified from the piping chart would not be included in Category IV.

SizePattern No.CodePED Categorisation
15mmPS500T243301SEP
22mmPS500T243303SEP
28mmPS500T243304SEP
Pegler Yorkshire reserve the right to change specifications

You must sign in to your My PY account to access specification clauses

loading...
Remember me
 

Register for a My PY account

BIM

You must sign in to your My PY account to access BIM Links

loading...
Remember me
 

Register for a My PY account

Included in your data sheet will be: (Please uncheck the details not required)

General Information

Dimensions

Flow Data

Guarantee / Warranty

Approvals

Pressure & Temperature

Care & Maintenance

Installation Instructions

Regulations

© 2022 Pegler. All Rights Reserved. Site Map  Social Media
Registered office: Aalberts Integrated Piping Systems Ltd, St Catherine's Ave, Doncaster, S Yorkshire, DN4 8DF Company no : 00401507

Legal: Privacy Policy  Cookie Policy  Modern Slavery Statement   Equal Opportunities  Terms & Conditions

PY Blog RSS twitter facebook link in youtube
Aalberts Industries